INFICON CUBE™ CDGSCI –  Capacitance Diaphragm Instrument

The Inficon CUBE™ CDGsci is the high end capacitance diaphragm instrument. The gauge is highly accurate (≤ 0.025 % Rd accuracy; ≤ 50 ppm FS Repeatability) and stable (< 5 ppm FS/ °C temperature stability; < 70 ppm FS/ year long term stability). The Inficon CUBEis the most appropriate device to standardize vacuum measurement systems and is the only choice for vacuum research applications. The product is designed with ultra-pure ceramic sensor that brings unique span stability throughout many years. The sensor is also proven temperature controlled, corrosion resistant, which helps maintain state-of-the-art zero stability.

Cube sets new standards in modern communication and user flexibility with a 20 Bit analog output and RS232-C, TCP / IP and HTML digital output connected through wireless or wired Ethernet interface. Each device comes with a quality assurance certificate, hand-signed by the Cube’s leading product researchers

Advantages

  • True high precision pressure measurement – Ceramic technology
  • Full stable output – Proven by PTB
  • Flexible communication – Various modern interfaces
  • All functions integrated – No controller required
  • Direct mounting to chamber – Optimized center of gravity
  • Transportation without isolation valve possible

Applications

  • Transfer standard
  • Main reference gauge
  • Research
  • In-house standard

—-

HystrongICL is a leading distributor of INFICON instruments in Vietnam, with an experienced technical team

Contact HystrongICL for more information! Contact now>>>

Facebook: HystrongICL

Hotline: (+84) 865.733.288 (call/zalo)

Specifications

Type 1000 Torr 100 … 1 Torr 100mTorr
Accuracy (1) % of reading 0.025 0.025 0.05
Temperature effect
on zero percent FS/°C 0.0005 0.0005 0.005
on span % of reading / °C 0.001 0.001 0.01
Pressure, max. bar (absolute) 3 2.5 1.5
Lowest reading percent FS 0.01 0.01 0.01
Lowest suggested reading percent FS 0.05 0.05 0.05
Temperature
Operation (ambient) °C +10 … +40 +10 … +40 +10 … +40
Storage °C –10 … +50 –10 … +50 –10 … +50
Supply voltage +14 … +30 VDC or ±15 V (±5%) +14 … +30 VDC or ±15 V (±5%) +14 … +30 VDC or ±15 V (±5%)
Power consumption
During Heat up W ≤20 ≤20 ≤20
At operating temperature W ≤17 ≤17 ≤17
Output signal (analog) V (dc) 0 … +10 0 … +10 0 … +10
Response time (2) ms 100 100 100
Degree of protection IP 40 IP 40 IP 40
Standards
CE conformity CE conformity EN 61000‑6‑2/-6-3, EN 61010 & RoHS EN 61000‑6‑2/-6-3, EN 61010 & RoHS EN 61000‑6‑2/-6-3, EN 61010 & RoHS
ETL certification ETL certification UL 61010‑1, CSA 22.2 No.61010‑1 UL 61010‑1, CSA 22.2 No.61010‑1 UL 61010‑1, CSA 22.2 No.61010‑1
SEMI compliance SEMI compliance SEMI S2 SEMI S2 SEMI S2
Electrical connection D-sub, 15 pole, male; 2 x LEMO Coax; Ethernet FCC D-sub, 15 pole, male; 2 x LEMO Coax; Ethernet FCC D-sub, 15 pole, male; 2 x LEMO Coax; Ethernet FCC
Setpoint
Number of setpoints Number of setpoints 2 (SP1,SP2) 2 (SP1,SP2) 2 (SP1,SP2)
Relay contact ≤30 ≤30 ≤30
Hysteresis percent FS 1 1 1
Diagnostic port
Protocol Protocol Web pages, REST services, RS232-ASCII Web pages, REST services, RS232-ASCII Web pages, REST services, RS232-ASCII
Read Read pressure, status, ID pressure, status, ID pressure, status, ID
Set Set set points, filter, zero adjust, factory reset, DC offset set points, filter, zero adjust, factory reset, DC offset set points, filter, zero adjust, factory reset, DC offset
Materials exposed to vacuum Aluminum oxide ceramic (AI2O3), stainless steel (AISI 316L (3)) Aluminum oxide ceramic (AI2O3), stainless steel (AISI 316L (3)) Aluminum oxide ceramic (AI2O3), stainless steel (AISI 316L (3))
Internal volume
I. volume DN 16 ISO KF cm³ (in.³) 4.2 (0.26) 4.2 (0.26) 4.2 (0.26)
I. volume DN 16 CF-R cm³ (in.³) 4.2 (0.26) 4.2 (0.26) 4.2 (0.26)
I. volume 8 VCR® cm³ (in.³) 4.2 (0.26) 4.2 (0.26) 4.2 (0.26)
Weight
Weight DN 16 ISO KF g 1670 1670 1670
Weight DN 16 CF-R g 1670 1670 1670
Weight 8 VCR® g 1670 1670 1670

Meanings:

  • (1) Non-linearity, hysteresis, repeatability at 25 °C ambient operating temperature without temperature effects after 2 hours operation.
  • (2) Increase 10 … 90 percent FS
  • (3) 18% Cr, 10% Ni, 3% Mo, 69% Fe

Part Numbers